Fluoroscopy

the_c-arm_pic

Refurbished and Remanufactured C-Arms

page_white_acrobat  Download OEC 9400 PDF Brochure 

9400_c_armAll c-arms undergo a multistep remanufacturing process. We take great pride in the fact that each unit is restored to a like-new status. Pain Management, Orthopaedics, Rehabilitation Services are just a few of the applications utilizing these remanufactured c-arms. The rotating x-ray tube allows for greater penetration and resolution for the lumbar area when doing needle localizations or other work involving the thicker anatomical areas of patients. For barium swallows a VCR or Digital Video Recorder can be utilized for better record keeping and post study analysis. The 1K X 1K CCD Technology used in this image system allows for crisp clear imaging. Whatever the purpose, any of these remanufactured c-arms will deliver the results you can depend on.

Mechanical repairs/cosmetic maintenance

  • All defective parts and covers are repaired or replaced           
  • C-arm is completely disassembled and repainted
  • “C” is removed from main frame assembly                  9600_c_armpage_white_acrobat Download OEC 9600 PDF Brochure
  • Horizontal arm removed, inspected and repaired as necessary
  • Vertical column removed and bearings removed inspected and replaced as required
  • X-ray tube removed and inspected for artifacts and internal integrity
  • Image intensifier removed and inspected for any imperfections and grid integrity
  • Camera removed
  • Wheels removed, cleaned and or replaced from main chassis
  • Chassis inspected for structural defects and repaired as necessary
  • Vertical lift assembly is tested for drift and adjusted/replaced if necessary
  • All bearings are inspected, cleaned and re-lubricated, or replaced as needed
  • Control panel display is tested and replaced if necessary
  • All wheels are inspected and lubricated and/or replaced as needed, with new cable pushers installed
  • All locks and brake assemblies are inspected, cleaned, and repaired or replaced as needed
  • C-arm is completely disassembled and repainted
  • Steering is tested and adjusted is required
  • Foot switch and hand switch provided on each unit
  • A complete set of operator and service manuals are provided

 9800_c_armRe-assembly

  •  All components sent to C-arm reassembly area for rebuilding
  • “C”, Image tube and camera,
  • Vertical column, main control and power cable installed
  • New batteries are installed
  • New CRT monitors installed in monitor cart
  • Monitor cart rebuilt
  • When C-arm is completely rebuilt mechanically system is sent for calibration and final testing  

     

  page_white_acrobat Download OEC 9800 PDF Brochure

 

 